Pages

Friday, June 3, 2016

LEARN THE CONCEPT OF CRITICAL & PSEUDOCRITICAL TEMPERATURE WITH THE EXAMPLE OF ENTONOX


▪️Entonox is Nitrous oxide mixed 50:50 with oxygen 

▪️It provides analgesia with maintenance of consciousness. 

▪️Usually administered via a demand valve for self administration. 

▪️Takes 30 seconds to act and continues for approx. 60 sec after inhalation has stopped 

▪️ For optimum effect inhalation should start when the contraction tightens. This will co-ordinate the maximal effect with the central painful part of the contraction. 

▪️20% N20 is equivalent to 15 mg of subcutaneous morphine. 

▪️ The optimal analgesic concentration was found to be 70% but some mothers lost consciousness at this concentration 

▪️ 50% N20 in oxygen is safer and this has become standard now

▪️ Entonox is the BOC trade name for this gas mixture.

▪️Poynting effect

The Poynting effect involves the dissolution of gaseous O2 when bubbled through liquid N2O, with vaporisation of the liquid to form a gaseous O2/N2O mixture.

▪️Critical & Pseudocritical temperature

๐Ÿ”นThe critical temperature of a gas is the maximum temperature at which compression can cause liquefaction. Or it is the temperature above which a substance cannot be liquefied however much pressure is applied. Mixing gases may change their critical temperature.

๐Ÿ”นThe pseudocritical temperature applies to a mixture of gases, such as Entonox, and is the temperature at which gas mixtures separate into their component parts. 

▪️The Poynting effect produces a 50:50 mixture which reduces the crtical temperature of N20 so Entonox has a pseudocritical temperature of -6 degree.

▪️Entonox 

 Highest -5.5°C @117 bar
 Cylinder -7°C @137 bar
 Pipeline -30°C @4 bar

▪️In cylinders it is supplied at a pressure of 137 bar and must be stored above its pseudocritical temperature of -6°C.  

▪️ Below this temperature the N2O liquefies in a process called lamination.  If this occurs a high concentration of O2 will be delivered first with little analgesic effect, but as the cylinder empties the mixture will become progressively more potent and hypoxic as it approaches 100% N2O. 

▪️If a cylinder has been exposed to cold below -6 degree C it should be warmed for 5 minutes in a 37 degree C water bath or for 2 hours in a room at 15 degree C. It should then be inverted three times before use.

▪️ When delivered via a pipeline at 4.1 bar the pseudocritical temperature is less than -30°C.

▪️Altitude per se has no effect on Entonox.

Reference: www.frca.uk


VEIN OF GALEN MALFORMATION: ANESTHESIA CONCERNS

▶️Vein Of Galen Malformation (VOGM) is a dilatation of the median vein of the procencephalon (which is a precursor of the Vein of Galen), caused by an arterio venous (A-V) shunt from the choroidal arteries of the anterior and posterior circulation. It can cause  A-V shunting and related systemic effects and hydrocephalus. 

▶️Incidence is less than 1% of cerebral vascular malformations.

▶️PROBLEMS:

✔️Most of the issues are due to the effect of A-V shunting

✔️Congestive Cardiac Failure and Pulmonary Hypertension : Due to A-V shunting . The etiology of cardiac failure may begin in utero. High output cardiac failure is associated with VGAM because 60 to 80% of aortic blood flow is directed through the VGAMS low resistant shunt. Blood flow travels through the VGAM during diastole creating a steal phenomenon. The reduction of diastolic pressure can lead to myocardial ischemia secondary to reduced coronary blood flow. 

 ✔️Ventriculomegaly : A-V shunting --> increased dural sinus pressure --> resistance to CSF entry to the sinus --> enlargement of ventricles


✔️Seizures

▶️INDICATIONS FOR DEFINITIVE MANAGEMENT: CCF, Hydrocephalus , Neurological symptoms

▶️TREATMENT

✔️Main goal of the treatment is to control the A-V shunt

✔️Endovascular embolization is the preferred treatment; other option is surgical clipping.

✔️Embolization of the feeding arteries and draining veins can result in reduction of blood flow through the VOGM which is the key to improved cardiac function and brain injury prevention.

✔️Embolization is less invasive and has a higher survival rate than open neurosurgical procedures. It provides better hemodynamic stability with minimal pain. Heart failure is an indication for urgent embolization. 

▶️ANESTHESIA CONCERNS

✔️Improving the cardiac function is the key to avoid multiple organ failure. The mortality rate for all neonates in heart failure undergoing transcatheter embolization can be up to 50%, mortality is much higher when pulmonary hypertension is present.

✔️Cardiac failure is difficult to treat and most beta agonists along with diuretics and Milrinone have been used with varying success. Although total systemic vascular resistance is reduced through the VOGM, the child in cardiac failure has an increased extracranial vascular resistance. So interventions that reduces extracranial systemic resistance is likely to improve systemic perfusion. Nitric oxide has been used to treat pulmonary hypertension in these patients.

✔️The goal is to achieve partial embolization with the endpoint of improving heart failure. So, the embolization may be staged. Each session is limited by the volume of contrast media delivered and the patient’s tolerance of the procedure. The ultimate goal of these sessions is to completely occlude the VOGM while avoiding neurological and cardiac injury

✔️Intracerebral hemorrhage due to venous hypertension is a potentially fatal complication of endovascular management. There is a thought that this complication can be avoided by staging the embolization procedure. Perforation of the venous sac can usually be managed by reversal of anticoagulation and continuation of coil embolization. Ischemic neurological deficits, Pulmonary embolization with embolic agents ( due to the high flow across the intracranial shunt that drains immediately into the central venous system) are other concerns. 

Reference: 
Anesthetic Implications of Neonatal Vein of Galen Aneurysmal Malformation (VGAM)  Ira S Landsman, Than Nguyen 

 


Thursday, June 2, 2016

๐Ÿ—ƒA FEW POINTS WHICH CAN MAKE AN ANESTHESIOLOGIST's LIFE EASIER๐Ÿ—ƒ


✔️CONVERSION OF SI UNITS TO NON SI UNITS

๐Ÿ”€ kilo Pascal to mm of  Hg ➡️multiply with 7.5

๐Ÿ”€ kilo Pascal to cm of H2O ➡️multiply with 10.2

๐Ÿ”€ blood sugar from mmol/l to mg/dl ➡️multiply with 18 

#SIunits , #nonSIunits

✔️AN EASIER FORMULA FOR CALCULATING 'IDEAL BODY WEIGHT'(IBW)

The Lemmens formula

Ideal weight (in kilograms) = 22 x (Height in meters)x2

✔️FORMULA FOR CALCULATING PLASMA OSMOLALITY (If using SI UNITS)

[2x (Na)] + [BUN] + [glucose]

✔️FORMULA FOR CALCULATING PLASMA OSMOLALITY (If using NON SI UNITS)

[2x (Na)] + [BUN / 2.8] + [glucose / 18]

Thursday, May 19, 2016

Practical Issues in blood transfusion in pediatrics

1. Amount of transfusion to be given: It has been seen that transfusion with PRBC at a dose of 20 mL/kg is well tolerated and results in an overall decrease in number of transfusions compared to transfusions done at 10 mL/kg. There is also a higher rise in hemoglobin with a higher dose of PRBCs.

 2. Properties of RBC products used in neonatal transfusion: a. RBCs should be freshly prepared and should not be more than 7 days old.  This translates into a high 2, 3-DPG concentration and higher tissue extraction of oxygen. 

3.Blood should be of newborn's ABO and Rh group. It should be compatible with any ABO or atypical red cell antibody present in the maternal serum.

4.   Volume and rate of transfusion: 
a. Volume of packed RBC = Blood volume (mL/kg) x (desired minus actual hematocrit)/ hematocrit of transfused RBC 
b. Rate of infusion should be less than 10 mL/kg/hour in the absence of cardiac failure. 
c. Rate should not be more than 2 mL/kg/hour in the presence of cardiac failure. 
d. If more volume is to be transfused, it should be done in smaller aliquots.

Tuesday, May 17, 2016

▶️ THE FETAL TRAP ๐Ÿค–


๐Ÿ”นThe placenta forms a barrier to the transfer of drugs between the mother and the fetus, but increasing lipid-solubility, decreasing maternal protein binding, decreasing molecular weight, increased materno-fetal concentration gradient and placental blood flow etc will increase the placental transfer of drugs

๐Ÿ”นThe relative distribution of the drug across the placenta is represented by Feto-Maternal (F/ M) concentration ratio

๐Ÿ”นPethidine and diamorphine are both metabolised in the fetus to less lipid-soluble products like norpethidine and morphine respectively, which remain on the fetal side of the placenta. The elimination half-lives of these drugs are also longer in the fetus because of immature hepatic metabolism. This again prolongs its existence in the fetal side.

๐Ÿ”นLipid solubility of drugs like thiopentone sodium are high; so they cross the placenta easily, and can accumulate as the pH is lower in the fetus

๐Ÿ”นDiazepam is metabolised to less lipid-soluble products. So it can have an F/ M ratio of 2 even one hour after maternal administration.

๐Ÿ”นLocal anaesthetic agents are weak bases which are largely UN-IONISED  at physiological pH, and cross the placenta readily. But fetal 'trapping' occurs in severe acidosis, when the molecules become IONIZED in the fetal side.

#pharmacology , #DrugMetabolism ,#PlacentalTransfer , #anesthesia

Tuesday, May 10, 2016

SI UNITS & NON SI UNITS OF PRESSURE


▪️Pressure is force applied over a unit area. Pressure  = Force/Area. It's SI unit is Pascal.

▪️️There are 7 base SI units , from which others are derived (which are known as derived SI units)

▪️Pascal is a derived SI unit. It is N.m-2. It is represented by the symbol Pa.

▪️One pascal is equal to a force of one newton applied over an area of one square metre. (N.m−2) 

▪️The pascal is a small amount (1 N is equal to just 102 g weight) 

▪️For this reason kilopascals (kPa) are used as standard.

▪️The standard atmospheric pressure is: 101.325 kPa = 1.013 bar = 14.696 psi =1 atm

Friday, May 6, 2016

VISCOUS FACTS❗️


⌛️Dynamic or absolute viscosity is a measure of the resistance of a fluid or gas to flow. It is measured using a viscometer or rheometer.

⌛️The SI unit of dynamic (or absolute) viscosity is the pascal-second (Pa·s), equivalent to N·s/ m2.

⌛️Viscosity is independent of flow rate

⌛️Viscosity is independent of pressure

⌛️️For a gas, viscosity decreases as its temperature increases 

⌛The relationship between viscosity and temperature and pressure only holds true for those fluids and gases that exhibit ‘Newtonian’ properties, i.e. substances that will always flow irrespective of forces acting upon them (e.g. crystalloid solutions and water). 

⌛️ Blood is a non-Newtonian fluid and its viscosity depends largely on haematocrit (and varies with flow rate).

⌛️Blood viscosity is increased by volatile anaesthetic agents, smoking and aging❗️

⌛️A thixotropic substance is one that becomes less viscous over time when agitated. If it becomes more viscous with agitation, this is known as a rheopectic material.

⌛️Kinematic velocity is defined as the dynamic velocity of a substance divided by its density.

Tuesday, May 3, 2016

ERRORS THAT CAN HAPPEN WITH THE SAMPLING FOR ARTERIAL BLOOD GAS ANALYSIS AND POSSIBLE CONSEQUENCES


❎AIR BUBBLES IN SYRINGE: may wrongly increase the Pao2 , Sao2 and pH

❎DILUTION OF THE SAMPLE WITH SALINE FLUSH OR HEPARIN: may wrongly increase Pao2 , while it decrease Paco2 , glucose, lactate , potassium and hemoglobin 

❎VENEPUNCURE DURING SAMLE COLLECTION: may wrongly decrease Po2 and So2 while it increases Pco2

❎ CLOTTING OF THE SAMPLE: may wrongly increase the potassium concentration 

#ABGerrors , #abg , #AbgSampling

ERRORS IN ABG SAMPLING: CAUSES & CONSEQUENCES



๐Ÿ”นReduced pH (anaerobic metabolism)
๐Ÿ”นReduced PaO2 (utilization of dissolved oxygen)
๐Ÿ”นRaised PaCO2 ( production of CO2 from continued metabolism)
๐Ÿ”นReduced glucose ( utilization if glucose stores)
๐Ÿ”นIncreased lactate( anaerobic metabolism)

#abg , #AbgErrors

CALCULATION OF THE VOLUME OF OXYGEN CYLINDER REQUIRED FOR A TRANSFER


▫️For this, we should know:
     1. Oxygen delivered = FiO2 x Minute Volume 
     2. Duration of the transfer

▫️For e.g. If we are expecting a duration of 2 hours (120 minutes) and we are having Size E cylinders and also need to deliver an FiO2 of 1 @ 6L / min

1. O2 delivered = 1 x 6 = 6L/ min
2. Size E has 660 L of O2, which will suffice for 660/6= 110 minutes ; so for 120 minutes, we need 2 cylinders 

#AnesthesiaGas , #OxygenCylinder